oneAPI Level Zero Loader v1 5 Released With VPU Driver

  • E80 Bobcat Compact Excavator Specifications

    E80 Bobcat Compact Excavator Specifications Operational Specifications Operating Weight - Canopy, standard arm, rubber tracks, bucket 18689 lb (8477 kg) - Add for steel tracks + 110 lb (55 kg) Ground Pressure - w/ standard 17.7" (450 mm) rubber tracks 5.7 psi (39.0 kPa)

    Learn More
  • Small Specalog for Cat 305E2 CR Mini Hydraulic Excavator

    All Cat Mini Excavators from 3.5 metric tons to 8 metric tons are ROPS, TOPS and Top Guard Level 1 certified and include the Cat Interlock (hydraulic lockout) System, a certified accumulator which allows for auxiliary pressure to be released, making connecting and disconnecting work tools safer and easier, and a travel alarm. All of these safety

    Learn More
  • Oil Leak Detection - Oil Alert

    The Oil Alert oil sensor only requires a small amount of oil (1/32 inch) seeping under Oil Alert activates it's loud "on/off" alarm and/or relay contact output. The OA model provides a 3 day audible oil detection alarm .

    Learn More
  • BACKHOE AND HYDRAULIC EXCAVATOR OPERATION

    4) Equipment 4) Engine compartment malfunction or for dirt, debris, oily damage, fire rags, tools, and leaks. hazard. Grasp engine covers firmly when removing. Avoid overreaching. Get help if needed. 5) Burns, splashed 5) Fluid levels. Wear fluids safety glasses with side shields and gloves. Remove tank caps or covers carefully. 6) Burns, high

    Learn More
  • HITACHI

    oil. 3. Fresh-air type, large-capacity air conditioner standard. 4. Auto-lubrication system for ensured lubrication of boom and arm pins optionally available. 5. Hitachi's original shockless valve and quick warm-up control system for engine and hydraulic oil means highly responsive controls immediately after start-up. 6. Round hydraulic tank

    Learn More
  • Caterpillar 314C Excavators Factory Service & Shop Manual

    Oil Leak Detection - Oil Alert

    Learn More
  • My caterpillar 305 excavator shut down and the oil

    Nov 14, 2016 · My caterpillar 305 excavator shut down and the oil pressure light and alarm went off. i checked the oil and its fine - Answered by a verified Technician Note: If Cat HYDO Advanced 10 hydraulic oil is used, the hydraulic oil change interval is extended to 3000 hours. S·O·S services may extend the oil change to a longer interval.

    Learn More
  • Symptoms of Common Hydraulic Problems and Their Root Causes

    Proactive maintenance emphasizes the routine detection and correction of root cause conditions that would otherwise lead to equipment failure. In the case of hydraulic systems, there are three easily detectable symptoms that give early warning of root cause conditions. These symptoms are abnormal noise, high fluid temperature and slow operation.

    Learn More
  • hydraulic oil temp warning light | Heavy Equipment Forums

    May 15, 2017 · Thank you, im guessing that alarm light is called hydr temp and wire is #40 light green going to "hydraulic temp switch" so this must be some kind of sensor in contact with hydraulic oil, when i find it somewhere check wires and possibly replace the switch? Just guessing

    Learn More
  • KUBOTA COMPACT EXCAVATOR KX KX91-3 SUPER SERIES 2

    smooth excavator operation. 3.Proportional flow auxiliary switch A convenient bi-directional switch enables easy operation of hydraulic thumbs and other hydraulic attachments such as augers and breakers. 4.2-speed travel switch The 2-speed travel switch is mounted on the dozer lever for easy operation and control, and advanced, user-friendly travel

    Learn More
  • Abbreviations Description - Kubota

    Mar 02, 2015 · A pre-operation inspection of Komatsu's PC360LC-11 Hydraulic Excavator.Learn more: https://bit.ly/2CHuTGs The PC360LC-11offers a closed Center Load Sensing

    Learn More
  • Case 580sl Hydraulic Light | Heavy Equipment Forums

    Dec 15, 2013 · Hello, Have a 2000 580sl Series 2 with 6,985 hours and been wondering about the hydraulic light. With the temps below freezing the light stays on for a while, until using the hydraulics for say 15 minutes. During this time the light will go off when using any hydraulics but comes on when you let up. RPM's must be over about 1500 to get the light.

    Learn More
  • KUBOTA COMPACT EXCAVATOR KX KX91-3 SUPER SERIES 2

    smooth excavator operation. 3.Proportional flow auxiliary switch A convenient bi-directional switch enables easy operation of hydraulic thumbs and other hydraulic attachments such as augers and breakers. 4.2-speed travel switch The 2-speed travel switch is mounted on the dozer lever for easy operation and control, and advanced, user-friendly travel

    Learn More
  • John Deere 75G Excavator Technical Service Manual

    John Deere 75G Excavator technical manual includes: 020102.02 - Engine Oil Pressure Alarm. 020105.02 - Hydraulic Oil Filter Restriction Alarm. 020106.02 - Air Cleaner Restriction Alarm. 020107.02 - Water Separator Alarm. 020109.02 - Pilot Control Shut-Off Lever Alarm.

    Learn More
  • Komatsu PC360LC-11 Hydraulic Excavator - Pre-Operation

    Mar 02, 2015 · A pre-operation inspection of Komatsu's PC360LC-11 Hydraulic Excavator.Learn more: https://bit.ly/2CHuTGs The PC360LC-11offers a closed Center Load Sensing

    Learn More
  • Caterpillar 313B Excavator Factory Service & Shop Manual

    Jan 02, 2019 · │ ├── Hydraulic Oil Cooler – Install.pdf │ ├── Hydraulic Oil Cooler – Remove.pdf │ ├── Alarm Indicator for Engine Oil Pressure Is Illuminated and Action Alarm Is Activated – Troubleshoot.pdf (304 CR and 305 CR Mini Hydraulic Excavators and 313B CR and 321B LCR Excavators Air Conditioning and Heating

    Learn More
  • Our 7130 was giving us an alarm for high hydraulic oil

    May 29, 2011 · Our 7130 was giving us an alarm for high hydraulic oil temperatures. We were running a 9' disc mower. The oil cooler was clean but still blew it out one more time. Went through the other troubleshooting ideas we read and could think of. What else would cause this problem?

    Learn More
  • Hydraulics Trouble Shooting Guide

    Hydraulic Fluid 1. suction line leaks 2. fluid level too low 3. wrongly designed reservoir 1. shaft packings or seals on the suction side defective 2. leakage - oil line terminates above fluid level 1. return terminates above fluid level 2. vortex effect due to wrongly laid lines …

    Learn More
  • TB260 - Compact Construction Equipment - Takeuchi US

    The safe start system requires the safety lockout lever be in the raised position in order to start the excavator ensuring hydraulic functions are inactive at start-up. The boom holding valve and overload alarm are designed to keep the boom from dropping if there is a sudden loss in pressure, and the overload alarm will sound (when ON) if you

    Learn More
  • John Deere 75G Excavator Technical Service Manual

    John Deere 75G Excavator technical manual includes: 020102.02 - Engine Oil Pressure Alarm. 020105.02 - Hydraulic Oil Filter Restriction Alarm. 020106.02 - Air Cleaner Restriction Alarm. 020107.02 - Water Separator Alarm. 020109.02 - Pilot Control Shut-Off Lever Alarm.

    Learn More